3 |
|
|a Sažetak na hrvatskom: Ultrazvuk je širenje poremećaja u mediju izazvano vanjskom pobudom u frekvencijskom području od 20 kHz do 1 GHz. U medicinskoj primjeni koristi se ultrazvuk frekvencije od 1 MHz do 50 MHz. Ultrazvuk se primjenjuje u više grana medicine; u dijagnostici, fizikalnoj terapiji, stomatologiji, dermatologiji, plastičnoj i rekonstruktivnoj kirurgiji... U medicini se primjenjuju efekti koje dobivamo primjenom ultrazvuka, Dopplerov efekt i efekt kavitacije.
Visokointenzitetno fokusiranje kod niskofrekvencijskih izvora postiže se direktnim dovođenjem mehaničke snage u određenu akustičku zonu. Posljednjih godina se usavršava primjena visokointenzitetnog ultrazvučnog polja.
Izlazna akustička snaga može se mjeriti uz pomoć tri metode: kalorimetrijskom, elektromehaničkom karakterizacijom te mjerenjem prostornog tlaka u bazenu bez odjeka. U ovom radu se posebno obradila kalorimetrijska metoda uz pomoć tri sonotrode pri dvije razike jakosti generatora ultrazvučnih valova.
|
520 |
3 |
|
|a Sažetak na engleskom: Ultrasound is spreading disorder in the medium caused by external excitation in frequency range from 20 kHz to 1 GHz. In medical applications are used frequencies from 1 MHz to 50 MHz. Ultrasound is used in many branches of medicine; in diagnostics, physical therapy, dentistry, dermatology, plastic and reconstructive surgery ... In medicine are applied ultrasound effects like Doppler effect and cavitation effect.
High intensity focusing in low frequency sources is achieved by applying direct mechanical power in a specific acoustic zone. The application of high intensity ultrasound fiel is getting improved in last few years.
Dissipated acoustic power can be measured using three methods:calorimetric method, electromechanical characterization and measuring derived acoustic power in the anechoic tank. In this paper is specialy described the calorimetric method with three different sonotrodes and with different intensity of ultrasound generator.
|
653 |
|
1 |
|a visokointenzitetni izvor ultrazvuka
|a parametri ultrazvučnog polja
|a metode mjerenja snage visokointenzitetnog ultrazvučnog izvora
|a koeficijent elektroakustičkog iskorištenja
|
653 |
|
1 |
|a high intensitiy ultrasound source
|a parameters of ultrasound field
|a methods of measuring power of high intensity ultrasound source
|a coefficient of electroacustic efficiency
|
700 |
1 |
|
|a Petošić, Antonio
|4 ths
|9 34970
|
942 |
|
|
|c Z
|2 udc
|
999 |
|
|
|c 45160
|d 45160
|