|a Proračun kratkog spoja u elektroenergetskim mrežama :
|b završni rad /
|c Ivica Pletikosa ; [mentor Marko Delimar].
|
246 |
1 |
|
|a Short-circuit calculations in electric power systems
|i Naslov na engleskom:
|
260 |
|
|
|a Zagreb,
|b I. Pletikosa,
|c 2015.
|
300 |
|
|
|a 37 str. ;
|c 30 cm +
|e CD-ROM
|
502 |
|
|
|b preddiplomski studij
|c Fakultet elektrotehnike i računarstva u Zagrebu
|g smjer: Elektroenergetika, šifra smjera: 34, datum predaje: 2015-06-12, datum završetka: 2015-07-13
|
520 |
3 |
|
|a Sažetak na hrvatskom: Određivanje najvećih struja kratkog spoja jedan je od najvažnijih proračuna u elektroenergetskom sustavu. Budući da je u stanju kratkog spoja, sustav izložen najvećim mehaničkim i termičkim naprezanjima, za ispravno vladanje sustava nužno je njegove elemente dimenzionirati prema strujama kratkog spoja. Ovim radom objašnjen je utjecaj izoliranja energetskih transformatora na određene tipove kratkog spoja. Pokazuje se da struje trofaznog i dvofaznog kratkog spoja ne reagiraju na ovakve promjene, dok struje jednofaznog i dvofaznog kratkog spoja sa zemljom padaju. Najznačajnije promjene događaju se na sabirnicama koje su direktno spojene na energetske transformatore, budući da tu dolazi do najveće promjene nulte impedancije. Za kratke spojeve na sabirnicama daleko od transformatora, ne dolazi do značajne promjene nulte impedancije pa time ni struja jednofaznog i dvofaznog kratkog spoja sa zemljom. Simulirani su pogonski uvjeti u kojima su dominantni dvofazni i dvofazni kratki spoj sa zemljom, i to na način da se proračun vršio sa stacionarnim reaktancijama generatora.
|
520 |
3 |
|
|a Sažetak na engleskom: Determening the amplitude of the dominant short circuit currents is one of the most important calculations in electric power systems. In the state of short circuit, the system is exposed to biggest mechanical and termical strains, so it is crucial to construct elements of the system, according to the currents that occur in the state of short circuit. In this paper, I have explained the effect of isolating power transformators on some short circuit faults. Results have shown that currents from three-phase and two-phase short circuit do not react on these changes, while circuits from one-phase and two-phase short circuit with ground drop in value. The most significant changes occur on busbars which are directly connected to the power transformators, becouse in that spot, the biggest changes in zero impedance appear. For short circuits that occur on busbars far from transformators, these changes are not significant. I have simulated operating conditions in which two-phase and two-phase short circuit with the ground are the dominant types of short circuit.
|
653 |
|
1 |
|a kratki spoj
|a elektroenergetske mreže
|a NEPLAN
|a transformatori
|
653 |
|
1 |
|a short-circuit
|a electric power systems
|a NEPLAN
|a transformator
|