Analytical aspects of selenium(+4)-rhodium(+3) interactions under voltammetric conditions

Abstract: Voltammetry of selenium(+4)-rhodium(+3) system was studied in different electrolyte solutions with special attention paid to possible application of the observed effects in selenite determination at trace levels. Although the signals obtained from such mixtures can be more than 200 times h...

Full description

Permalink: http://skupni.nsk.hr/Record/nsk.NSK01000716810/Details
Matična publikacija: Croatica chemica acta
81 (2008), 4 ; str. 665-672
Glavni autor: Zelić, Marina, kemičarka (-)
Ostali autori: Strmečki Kos, Slađana (-)
Vrsta građe: Članak
Jezik: eng
Predmet:
Online pristup: CROATICA CHEMICA ACTA
LEADER 02019caa a2200301 ir4500
001 NSK01000716810
003 HR-ZaNSK
005 20220322173229.0
007 ta
008 091021s2008 ci ||| ||eng
035 |9 (HR-ZaNSK)719381 
035 |a (HR-ZaNSK)000716810 
040 |a HR-ZaNSK  |b hrv  |c HR-ZaNSK  |e ppiak 
041 0 |a eng  |b hrv 
042 |a croatica 
080 |a 54  |2 MRF 1998. 
100 1 |a Zelić, Marina,  |c kemičarka 
245 1 0 |a Analytical aspects of selenium(+4)-rhodium(+3) interactions under voltammetric conditions /  |c Marina Zelić, Slađana Strmečki. 
300 |b Ilustr. 
504 |a Bibliografija: 19 jed. 
504 |a Sažetak 
520 8 |a Abstract: Voltammetry of selenium(+4)-rhodium(+3) system was studied in different electrolyte solutions with special attention paid to possible application of the observed effects in selenite determination at trace levels. Although the signals obtained from such mixtures can be more than 200 times higher than those resulting from simple selenium(+4) solutions without rhodium(+3) added, it remains questionable how such results could be applied in practice. The main problem is data treatment because (generally) current – concentration plot is not a straight line with zero intercept. Additionally, its shape changes with the selenite concentration range. The problem is illustrated taking as an example selenium(+4) determination in solutions of selenium(+6). At present, results obtained in the system of interest seem to be important as phenomena and possible indicators of some catalytic processes. Before their application in trace analysis the answers to some general questions should be found 
653 0 |a Selen  |a Rodij  |a Voltametrija  |a Pravokutnovalna voltametrija 
700 1 |a Strmečki Kos, Slađana 
773 0 |t Croatica chemica acta  |x 0011-1643  |g 81 (2008), 4 ; str. 665-672  |w nsk.(HR-ZaNSK)000001621 
981 |b B09/08  |p CRO 
998 |a rado091021  |c vol2o120830 
856 4 2 |u http://public.carnet.hr/ccacaa/  |y CROATICA CHEMICA ACTA