Comparative analysis of an off-grid PV system for different types of batteries
The aim of this paper is to find an optimal size of different components of an off-grid PV system in the HOMER software with different types of batteries (lead-acid batteries and lithium-ion batteries). The proposed model shows the optimal size of the off-grid PV system for a holiday cottage with re...
Permalink: | http://skupni.nsk.hr/Record/nsk.NSK01001041816/Details |
---|---|
Matična publikacija: |
International journal of electrical and computer engineering systems (Online) 9 (2018), 1 ; str. 11-19 |
Glavni autori: | Raff, Rebeka (Author), Golub, Velimir, Perko, Jurica |
Vrsta građe: | e-članak |
Jezik: | eng |
Predmet: | |
Online pristup: |
https://doi.org/10.32985/ijeces.9.1.3 International journal of electrical and computer engineering systems (Online) Hrčak |
LEADER | 02366naa a22003734i 4500 | ||
---|---|---|---|
001 | NSK01001041816 | ||
003 | HR-ZaNSK | ||
005 | 20191018112321.0 | ||
006 | m d | ||
007 | cr|||||||||||| | ||
008 | 190926s2018 ci a |o |0|| ||eng | ||
024 | 7 | |2 doi |a 10.32985/ijeces.9.1.3 | |
035 | |a (HR-ZaNSK)001041816 | ||
040 | |a HR-ZaNSK |b hrv |c HR-ZaNSK |e ppiak | ||
041 | 0 | |a eng |b eng | |
042 | |a croatica | ||
044 | |a ci |c hr | ||
080 | 1 | |a 621.3 |2 2011 | |
100 | 1 | |a Raff, Rebeka |4 aut | |
245 | 1 | 0 | |a Comparative analysis of an off-grid PV system for different types of batteries |h [Elektronička građa] / |c Rebeka Raff, Velimir Golub, Jurica Perko. |
300 | |b Ilustr. | ||
504 | |a Bibliografija: 19 jed. | ||
504 | |a Abstract. | ||
520 | |a The aim of this paper is to find an optimal size of different components of an off-grid PV system in the HOMER software with different types of batteries (lead-acid batteries and lithium-ion batteries). The proposed model shows the optimal size of the off-grid PV system for a holiday cottage with regard to eligibility criteria for various types of batteries and the net present cost (NPC). The observed off-grid PV system consists of PV modules, a load, a converter and batteries and it is modelled in the HOMER software. The load is modelled with a daily load diagram for the holiday cottage. For lead-acid and lithium-ion batteries the optimal size of different components of an off-grid PV system for five different scenarios (in respect of the price and life-time) is obtained. In addition, the optimal size of the presented model with respect to different values of capacity shortage ranging from 0% to 5% is presented. | ||
653 | 0 | |a Baterije |a Fotonaponski sustavi |a Izvanmrežni rad | |
700 | 1 | |a Golub, Velimir |4 aut | |
700 | 1 | |a Perko, Jurica |4 aut | |
773 | 0 | |t International journal of electrical and computer engineering systems (Online) |x 1847-7003 |g 9 (2018), 1 ; str. 11-19 |w nsk.(HR-ZaNSK)000739692 | |
981 | |b Be2018 |b B02/18 | ||
998 | |b tino1910 | ||
856 | 4 | 0 | |u https://doi.org/10.32985/ijeces.9.1.3 |
856 | 4 | 0 | |u http://www.etfos.unios.hr/ijeces/papers/comparative-analysis-of-an-off-grid-pv-system-for-different-types-of-batteries/ |y International journal of electrical and computer engineering systems (Online) |
856 | 4 | 1 | |y Digitalna.nsk.hr |
856 | 4 | 0 | |u https://hrcak.srce.hr/213960 |y Hrčak |