Harmonic interaction of a static Var compensator with AC power system containing multiple non-linear loads

In this paper a study of the impact of the harmonics generated by a static Var compensator (SVC) is presented. The SVC is modeled, in the harmonic domain, as a coupled current source by using the complex Fourier transforms. Then, this model is converted to polar form to be integrated into the harmon...

Full description

Permalink: http://skupni.nsk.hr/Record/nsk.NSK01001084008/Details
Matična publikacija: Engineering review (Online)
40 (2020), 3 ; str. 21-31
Glavni autori: Nassim Kraimia, Mohamed (Author), Boudour, Mohamed
Vrsta građe: e-članak
Jezik: eng
Predmet:
Online pristup: https://doi.org/10.30765/er.40.3.03
Hrčak
LEADER 02117naa a22003494i 4500
001 NSK01001084008
003 HR-ZaNSK
005 20210127160514.0
006 m d
007 cr||||||||||||
008 201210s2020 ci a |o |0|| ||eng
024 7 |2 doi  |a 10.30765/er.40.3.03 
035 |a (HR-ZaNSK)001084008 
040 |a HR-ZaNSK  |b hrv  |c HR-ZaNSK  |e ppiak 
041 0 |a eng  |b eng 
042 |a croatica 
044 |a ci  |c hr 
080 1 |a 621.3  |2 2011 
100 1 |a Nassim Kraimia, Mohamed  |4 aut  |9 HR-ZaNSK 
245 1 0 |a Harmonic interaction of a static Var compensator with AC power system containing multiple non-linear loads  |h [Elektronička građa] /  |c Mohamed Nassim Kraimia, Mohamed Boudour. 
300 |b Ilustr. 
504 |a Bibliografija: 22 jed. 
504 |a Abstract. 
520 |a In this paper a study of the impact of the harmonics generated by a static Var compensator (SVC) is presented. The SVC is modeled, in the harmonic domain, as a coupled current source by using the complex Fourier transforms. Then, this model is converted to polar form to be integrated into the harmonic power flow program. This approach has been carried out on the IEEE 14 bus test power system, in order to show its effectiveness in evaluating the impact of harmonics, injected by the shunt compensating devices, and its interaction with the AC transmission system, in meshed power networks. Since the SVC consists of a thyristorcontrolled reactor (TCR) and a fixed capacitor, the harmonic currents are functions of the TCR thyristors firing angles. The variation of the total voltage harmonic distortion as function of firing angle changes and location of nonlinear loads is clearly presented and discussed. 
653 0 |a Statički VAR kompenzator  |a Harmonijski protok snage  |a Struja 
700 1 |a Boudour, Mohamed  |4 aut  |9 HR-ZaNSK 
773 0 |t Engineering review (Online)  |x 1849-0433  |g 40 (2020), 3 ; str. 21-31  |w nsk.(HR-ZaNSK)000848891 
981 |b Be2020  |b B02/20 
998 |b tino2101 
856 4 0 |u https://doi.org/10.30765/er.40.3.03 
856 4 0 |u https://hrcak.srce.hr/238262  |y Hrčak 
856 4 1 |y Digitalna.nsk.hr