A medium frequency transformer design for spot welding machine using sizing equation and finite element analysis

In this study, a medium frequency power transformer has been designed analytically and its sizes have been obtained. The transformer’s analyses were made numerically by 2D AnsysMaxwell Solver software package. The Solver has also helped to study suitable transformer core and winding samples. Unlike...

Full description

Permalink: http://skupni.nsk.hr/Record/nsk.NSK01001084010/Details
Matična publikacija: Engineering review (Online)
40 (2020), 3 ; str. 42-51
Glavni autori: Arslan, Serdal (Author), Tarimer, İlhan, Güven, M. E., Akkaya Oy, Sibel
Vrsta građe: e-članak
Jezik: eng
Predmet:
Online pristup: https://doi.org/10.30765/er.40.3.05
Hrčak
LEADER 02232naa a22003734i 4500
001 NSK01001084010
003 HR-ZaNSK
005 20210126144213.0
006 m d
007 cr||||||||||||
008 201210s2020 ci d |o |0|| ||eng
024 7 |2 doi  |a 10.30765/er.40.3.05 
035 |a (HR-ZaNSK)001084010 
040 |a HR-ZaNSK  |b hrv  |c HR-ZaNSK  |e ppiak 
041 0 |a eng  |b eng 
042 |a croatica 
044 |a ci  |c hr 
080 1 |a 621  |2 2011 
100 1 |a Arslan, Serdal  |4 aut  |9 HR-ZaNSK 
245 1 2 |a A medium frequency transformer design for spot welding machine using sizing equation and finite element analysis  |h [Elektronička građa] /  |c Serdal Arslan, İlhan Tarimer, M. E. Güven, Sibel Akkaya Oy. 
300 |b Graf. prikazi. 
504 |a Bibliografija: 38 jed. 
504 |a Summary. 
520 |a In this study, a medium frequency power transformer has been designed analytically and its sizes have been obtained. The transformer’s analyses were made numerically by 2D AnsysMaxwell Solver software package. The Solver has also helped to study suitable transformer core and winding samples. Unlike medium frequency transformer, which is generally driven by unipolar PWM method, the designed transformer is driven by bipolar PWM method in the study. The core losses were obtained for different core materials (Trafoperm N3 and Amorfous 2605SA1) by AnsysMaxwell numerical and analytical calculations. The calculated losses for no-load working conditions were compared with each other. The designed transformer has been analyzed for its noload and loaded working conditions magnetically. Finally, the radial and axial forces created in the windings have also been examined for loaded working condition. 
653 0 |a Transformatori  |a Točkasto zavarivanje  |a Analiza konačnih elemenata 
700 1 |a Tarimer, İlhan  |4 aut  |9 HR-ZaNSK 
700 1 |a Güven, M. E.  |4 aut  |9 HR-ZaNSK 
700 1 |a Akkaya Oy, Sibel  |4 aut  |9 HR-ZaNSK 
773 0 |t Engineering review (Online)  |x 1849-0433  |g 40 (2020), 3 ; str. 42-51  |w nsk.(HR-ZaNSK)000848891 
981 |b Be2020  |b B02/20 
998 |b dalo2101 
856 4 0 |u https://doi.org/10.30765/er.40.3.05 
856 4 0 |u https://hrcak.srce.hr/238264  |y Hrčak 
856 4 1 |y Digitalna.nsk.hr