Reconciling architectural design with seismic codes

Seismic codes include strict requirements for the design and construction of mid-rise reinforced concrete residential buildings. These requirements call for the symmetric and regular arrangement of the structural system, increased cross-sections for columns, and the introduction of shear walls to co...

Full description

Permalink: http://skupni.nsk.hr/Record/nsk.NSK01001131357/Details
Matična publikacija: Prostor (Online)
29 (2021), 1(61) ; str. 42-55
Glavni autor: Ozmen, Cengiz (Author)
Vrsta građe: e-članak
Jezik: eng
Predmet:
Online pristup: https://doi.org/10.31522/p.29.1(61).4
Hrčak
LEADER 02500naa a22003494i 4500
001 NSK01001131357
003 HR-ZaNSK
005 20220502095330.0
006 m d
007 cr||||||||||||
008 220314s2021 ci ad |o |0|| ||eng
024 7 |2 doi  |a 10.31522/p.29.1(61).4 
035 |a (HR-ZaNSK)001131357 
040 |a HR-ZaNSK  |b hrv  |c HR-ZaNSK  |e ppiak 
041 0 |a eng 
042 |a croatica 
044 |a ci  |c hr 
080 1 |a 72  |2 2011 
100 1 |a Ozmen, Cengiz  |4 aut 
245 1 0 |a Reconciling architectural design with seismic codes  |h [Elektronička građa] :  |b a comparative architectural analysis for mid-rise reinforced concrete residential buildings in Turkey /  |c Cengiz Özmen. 
300 |b Ilustr., graf. prikazi. 
504 |a Bibliografija i izvori: 23 jed. 
504 |a Summary. 
520 |a Seismic codes include strict requirements for the design and construction of mid-rise reinforced concrete residential buildings. These requirements call for the symmetric and regular arrangement of the structural system, increased cross-sections for columns, and the introduction of shear walls to counteract the effects of lateral seismic loads. It is challenging for architects to reconcile the demands of these codes with the spatial arrangement and commercial appeal of their designs.This study argues that such reconciliation is possible through an architectural analysis. First, the effectiveness of applying the seismic design principles required by the codes is demonstrated with the comparative analysis of two finite element models. Then three pairs of architectural models, representing the most common floor plan arrangements for such buildings in Turkey, are architecturally analyzed before and after the application of seismic design principles in terms of floor area and access to view. The results demonstrate that within the context defined by the methodology of this study, considerable seismic achievement can be achieved in mid-rise reinforced concrete residential buildings by the application of relatively few, basic design features by the architects. 
653 0 |a Arhitektonsko projektiranje  |a Stambene zgrade  |a Armirani beton  |a Seizmičko projektiranje 
653 5 |a Turska 
773 0 |t Prostor (Online)  |x 1333-9117  |g 29 (2021), 1(61) ; str. 42-55  |w nsk.(HR-ZaNSK)000261885 
981 |b Be2021  |b B02/21 
998 |b dalo2205 
856 4 0 |u https://doi.org/10.31522/p.29.1(61).4 
856 4 0 |u https://hrcak.srce.hr/259522  |y Hrčak 
856 4 1 |y Digitalna.nsk.hr